• Home
  • ABOUT US
    • Certificate
    • Exhibition
  • Products
    • Distribution Apparatus
      • RCBO
      • MCB
      • MCCB
      • Modular Contactor
      • RCCB/RCD/ELCB
      • Consumer Unit
      • Waterproof Junciont Box
      • Busbar
      • Disconnector
    • Industrial Control
      • Industrial Contactor
  • Services
    • FAQs
    • Catalogue Download
    • Import Duty-Free
  • News
  • Contact
English English 
  • Русский Русский
  • Русский Español

TONGOU Electrical TONGOU Electrical TONGOU Electrical TONGOU Electrical

For More Information
English English 
  • Русский Русский
  • Español Español
Menu
  • Home
  • ABOUT US
    • Certificate
    • Exhibition
  • Products
    • Distribution Apparatus
        • 1-2-500×500RCBO
        • MCCB-500x500MCCB
        • 1-8-500x500MCB
        • 1-17-500x500Modular Contactor
        • 1-7-300x300-500x500SPD
        • 2-27-500x500RCCB/RCD/ELCB
        • 1-5-500x500Waterproof Junciont Box
        • 0-500x500Busbar
        • 1-15-500x500Disconnector
        • flush-mounting-distribution-consumer-unit-63A-2P-RCD-circuit-breaker-protection-metal-base-box-500x500Consumer Unit
    • Industrial Control
        • 5-1-500x500Industrial Contactor
  • Services
    • News
    • FAQs
    • Catalogue
    • Import Duty-Free
  • Contact
elcbhot1
  • RCCB/RCD
  • Miniature Circuit breaker
  • EV Charging Power System
  • How to connect miniature circuit breaker (MCB) for DC 12-1000V?

      HOME > NEWS > How to connect miniature circuit breaker (MCB) for DC 12-1000V?

      Latest News

      • How to connect miniature circuit breaker (MCB) for DC 12-1000V?
        08/10/2020
      • ELEKTRO 2019 (EXPO CENTR) In Moscow, Russia
        07/09/2019
        This is the fourth time we have come to Moscow to participate in the Power…
      • RCCB is used in the elevator system
        10/22/2018
        RCCB: Residual Current Circuit Breaker. Type: A and AC.RCCB is aimed to used to protect…
      • The next energy age belongs to…
        07/06/2018
        With the development of industry, people pay more and more attention to environmental protection. Solar…

      How to connect miniature circuit breaker (MCB) for DC 12-1000V?

      • What is the DC miniature circuit breaker (MCB)?
      • How to connect DC MCB correctly?
      • Does AC MCB apply to DC states?

      What is the DC miniature circuit breaker (MCB)?

      The functions of DC MCB and AC MCB are the same. They both protect electrical appliances and other load equipment from overload and short-circuit problems, and protect the circuit safety. but the usage scenarios of AC MCB and DC MCB are different. It generally depends on whether the voltage used is alternating current states or direct current states. Most of DC MCB uses some direct current systems like new energy, solar PV, etc. The voltage states of DC MCB is generally from DC 12V-1000V.

      The difference between AC MCB and DC MCB by only physical parameters, the AC MCB has labels of the terminals as LOAD and LINE terminals whereas the DC MCB will have positive (+) or negative (-) sign on its terminal.

      How to connect DC MCB correctly?

      Due to the DC MCB has a marking of ‘+’ and ‘-’ symbol only, it is often easy to connect incorrectly. If the DC miniature circuit breaker is connected or wired incorrectly, there are possibilities of problems occurring. In case of overload or short circuit, the MCB will not be able to cut the current and put out the arc, this may lead to the breaker burning out.

      Therefore, DC MCB has a marking of ‘+’ and ‘-’ symbols, still need to mark the circuit direction and wiring diagrams, as shown below:

      2P-550V-DC-MCB
      connect-2P-550V-DC-MCB-correctly

      2P  550V

      4P-1000V-DC-MCB
      connect-4P-1000V-DC-MCB-correctly

      4P  1000V

      According to the wiring diagram, 2P DC MCB has two wiring methods, one is the top is connected to the positive and negative poles, another method is the bottom is connected to the positive and negative poles as the marking of ‘+’ and ‘-’. For 4P 1000V DC MCB has Three wiring methods, according to different usage states, to choose the corresponding wiring diagram to connect the wiring.

      Does AC MCB apply to DC states?

      The AC current signal is continuously changing its value for each second. The AC voltage signal changes from positive to negative in every second of a minute. The MCB arc will be extinguished at 0 Volts, the wiring will be protected from a huge current. But the DC signal is not alternating, it flows in a constant state and the value for the voltage is only changed when the circuit is trip OFF or the circuit is decreased by some value. Otherwise, the DC circuit will supply a constant value of voltage for each second of a minute. So, as there is no 0 Volt point in a DC state, it doesn’t suggest that AC MCB applies to DC states.

      certification

      Related Products

      High Quality 32 amp rcbo Residual Current Circuit Breaker With Overcurrent Protection

      High Quality 32 amp rcbo Residual Current Circuit Breaker With Overcurrent Protection

      TOBD5-63 RCBO 16A-50A 30mA 6KA 1P+N Residual Current Circuit Breaker With Overcurrent Protection

      TOBD5-63 RCBO 16A-50A 30mA 6KA 1P+N Residual Current Circuit Breaker With Overcurrent Protection

      TORD6B-63 4Pole Type B RCD 16A-63A 30mA Residual Current Circuit Breaker RCCB

      TORD6B-63 4Pole Type B RCD 16A-63A 30mA Residual Current Circuit Breaker RCCB

      TORD6B-63 2Pole Type B RCD 16A-63A 30mA Residual Current Circuit Breaker RCCB

      TORD6B-63 2Pole Type B RCD 16A-63A 30mA Residual Current Circuit Breaker RCCB

      18 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      18 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      12 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      12 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      6 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      6 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      4 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      4 Ways IP66 PC Waterproof Distribution Box Switch Box Breaker Box

      About US

      Established in 1993, Tongou electrical focus on the electricity safety products for household, commercial, industrial and similar installations, Such as Miniature Citcuit Breaker (MCB), Residual Current Circuit Breaker(RCCB), Residual Current Circuit Breakers with Over-current Protection(RCBO), Switch-Disconnector, Distribution Box, Moulded case circuit breaker(MCCB), air circuit breaker(ACB), AC Contactor, Magnetic Starter, Motor Protection Circuit Breaker and Thermal Relay etc.

      PRODUCT LIST

      Distribution Apparatus

      Industrial Control

      Consumer Unit

      MCB

      MCCB

      Modular Contactor

      RCBO

      RCCB/RCD/ELCB

      Industrial Contactor

      Thermal Relay

      Contact US

      map_76.968105065666px_1152927_easyicon.net

      Manufacturer Address

      Paidong Industrial Zone Qiligang,Yueqing City,Zhejiang province,China.

      phone

      Phone No

      +86-577-62676885

      mail_179.02097902098px_1188260_easyicon.net

      E-Mail

      elcb@elcb.net

      dh

      Mobile

      +86-15325075111

      whatsapp

      WhatsApp

      +86-15325075111

      Onlie Store(Sample Order):
      sumaitong EBAY amazon
      Skype QQ Wechat
      Copyrights © TONGOU Electrical
      • Home
      • ABOUT US
        • Certificate
        • Exhibition
      • Products
        • Distribution Apparatus
          • RCBO
          • MCB
          • MCCB
          • Modular Contactor
          • RCCB/RCD/ELCB
          • Consumer Unit
          • Waterproof Junciont Box
          • Busbar
          • Disconnector
        • Industrial Control
          • Industrial Contactor
      • Services
        • FAQs
        • Catalogue Download
        • Import Duty-Free
      • News
      • Contact
      TONGOU Electrical